Balance · 7
Tweaked balance for direct and passthrough heat exchangers.
direct and passthrough heat exchanger balanceTweaked heat exchanger balance.
heat exchanger balanceImproved the multi-grid venting algorithm so medium and large powered vents draw gas from surrounding grids more predictably.
powered vent multi-grid venting algorithmMedium and large powered vents now only pull from neighbouring grids when their local grid is close to vacuum.
powered vent grid pulling conditionChanged the existing heat exchanger internal area to match the large direct heat exchanger.
existing heat exchanger internal areaPowered vents may now temporarily exceed their target external pressure when moving gas into the world.
powered vent external pressure behaviourUpdated heat exchanger values to be in line with radiator values.
heat exchanger value
Content · 15
New powered vents added that draw gas from surrounding grids and output large amounts of gas, useful for pulling vacuums or filling rooms quickly.
powered ventAdded a 2x2 Powered Vent designed for larger airlocks, able to efficiently vacuum small-medium rooms.
powered vent (medium)Added a Kit for the small direct heat exchanger with a pipe bender recipe.
small direct heat exchanger kitAdded a large direct heat exchanger.
large direct heat exchangerAdded a kit for the Powered Vent.
powered vent kitAdded sounds to Powered Vents.
powered vent soundDirect heat exchangers added with two inputs that equalize energy between two networks, in large and small sizes, each in gas+gas, gas+liquid and liquid+liquid variants.
direct heat exchangerAdded a Kit for the large direct heat exchanger with a tier 2 pipe bender recipe.
large direct heat exchanger kitBasic and hard suits received updated, higher-fidelity visuals while keeping the same look.
suit visualAdded a 3x3 Large PoweredVent for pulling vacuums on large airlocks and hangars.
large powered ventThe emergency suit was completely reworked so it is clearly different from the basic suit.
emergency suit reworkAdded three variants of the small direct heat exchanger (gas+gas, gas+liquid, liquid+liquid); tooltip still needs to be added.
small direct heat exchanger variantAdded a passthrough heat exchanger in three variants.
passthrough heat exchangerRemoved the old heat exchanger from the kit.
old heat exchanger kitRemoved Split Interactables from the Large Direct Heat Exchanger Kit.
large direct heat exchanger kit interactable
Economy · 4
Removed the ItemKitRoverMKI recipe from the electronics printer.
electronics printer recipeChanged the existing heat exchanger kit recipe to require Invar and moved it to the tier 2 pipe bender.
heat exchanger kit recipe and locationAdded the Kit (PoweredVent) recipe to the tier 2 pipe bender.
powered vent kit crafting recipeFixed passthrough heat exchanger construction consuming a welder instead of steel sheets.
passthrough heat exchanger construction cost
System · 2
Airlock, AirControl and Logic motherboards now use IPoweredVent for vent device connections.
motherboard vent connectionAdded an IPoweredVent interface for connecting powered vents to circuit boards that interact with active vents.
powered vent circuit interface
UI · 7
Added energy exchanged to the tooltip on the physical input panel.
energy exchanged tooltipAdded a flow rate indicator and flow-rate tooltip to the active vent.
flow rate indicator and tooltipUpdated smoothness for the new suit materials.
new suit material smoothnessFixed thumbnails for the large direct heat exchanger kit.
large direct heat exchanger kit thumbnailPowered vents and the active vent gained a flow rate indicator showing whether they receive enough gas to work at full capacity.
flow rate indicatorAdded a flow rate indicator to PoweredVent that glows orange/red when flow is limited by output pipe pressure or capacity.
flow rate indicator glowAdded missing descriptions to the heat exchangers.
heat exchanger description
Fix · 25
Re-enabled active vents being able to burst pipes, removing the internal pressure limiting concept.
active vent pipe burstingFixed direct heat exchanger input connection orientation so pipes connect from the correct end.
direct heat exchanger input orientationRemoved an unused heat exchanger kit prefab.
unused heat exchanger kit prefabUpdated helmet visor materials.
helmet visor materialFixed the Condensation Valve blueprint.
condensation valve blueprintFixed CondensationChamber having its pipe tooltips flipped.
condensation chamber pipe tooltipAdded missing broken states to the large direct heat exchanger.
large direct heat exchanger broken stateFixed the mixer not throughputting gas when set to 100 and the other input pipe was empty.
mixer gas throughputFixed large direct and passthrough heat exchangers not requiring frame support.
frame support requirementFixed an index out of range exception thrown by StringManager.
index out of range exceptionCleaned up ResetVent function calls for the active vent, which were not being called from the correct function.
active vent reset function callUpdated incorrectly set smoothness values for some materials.
material smoothness valueFixed backpacks being invisible in suit storage.
backpack visibility in suit storageFixed error spam from the plant cartridge when trying to display the value 1000.
error spam when displaying value 1000Fixed incorrect position on the powered vent blueprint.
powered vent blueprint positionFixed tooltip not syncing for clients on the direct heat exchanger.
direct heat exchanger tooltip syncFixed an incorrectly named heat exchanger kit that caused an error when populating the Stationpedia.
heat exchanger kit naming errorFixed the phase-change diagram showing on stationpedia pages where it should be hidden when resizing the window.
stationpedia phase-change diagram visibilityFixed invisible build states on the large direct heat exchanger.
large direct heat exchanger build stateFixed safety limits being ignored on the active vent.
safety limits ignoredFixed inputs and outputs on large and passthrough heat exchangers.
large and passthrough heat exchanger inputs and outputUpdated UVs for the basic suit mesh.
basic suit mesh uvAdded missing large direct heat exchangers to the world manager.
large direct heat exchanger world spawningFixed PoweredVents build and broken states using the incorrect material.
powered vent build and broken state materialFixed the powered vent mode switch being in the incorrect colour state when first placed.
powered vent mode switch colour
Also in this patch3
Removed internal pressure logic type as a read/write value for the active vent.
internal pressure logic type read/writeChanged Kit (heat exchanger) back to its original values.
heat exchanger kit recipe valueReverted earlier active vent changes.
active vent changes reverted


